Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring
Home > Products > Gas Analysers > Mercury (Hg) analysers > Automatic mercury stack gas monitor SM-3

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Automatic mercury stack gas monitor SM-3

The SM-3 mercury analyzer measures continuously the elemental, bound and ionic mercury in stack fluegas

Automatic mercury stack gas monitor SM-3

The SM-3 mercury analyzer measures continuously the elemental, bound and ionic mercury in stack fluegas

The operating principle of the SM-3 is based on a completely new technique: mercury compounds cracking and the reduction of ionic mercury contained in stack gas is performed applying the thermocatalytic method.

Wet chemical sample gas treatment using reagents and bubblers is avoided. Maintenance and servicing of the SM-3 are therefore extremely easy.

Exemple of use:
May also be used for mobile applications.

FEATURES & BENEFITS

  • True continuous mercury measurement (not measuring cycle)
  • No wet-chemistry, no use of reagents
  • Maintenance-free solid state catalyst
  • Range 1 to 45; 0 to 75; 0 to 500 µg/m³ Hg (other ranges upon request)
  • Corrosion protected, rugged construction
  • Compact size, mobile operation possible
  • Detects elemental, ionic and bound mercury


MAIN APPLICATIONS

  • Coal fired power plants
  • Municipal waste incinerators
  • sewage sludge incinerators
  • Hazardous waste incinerators
  • Cement production
  • Thermal soil resanitation plants
  • Wood combustors using recycled wood
  • Metal recycling furnaces

TECHNICAL SPECIFICATIONS
Signal outputs analogue: 4 – 20 mA (max. 500 Ω); serial: RS 232; Modbus (option)
Status output 3 x pairs of relay contacts (dry contacts)
Max. sample temperature 200 °C
Ambient temperature range allowed 5 – 40 °C
Sample line length 30 m
Power supply 230 VAC / 50 Hz (110 VAC / 60 Hz option)
El. Power consumption Analyzer: max. 100 VA; sample line: max. 150 VA / meter
Dimensions (W x H x D) approx. 55 x 160 x 70cm (mounted on stand)
Weight approx. 50 kg

TECHNICAL DATA
Measuring principle thermocatalytic reduction at stack, cold vapor atomic absorption (CVVAAS) at 253.7 nm
Measured component Total Gaseous Mercury (TGM)
UV-Source Electrodeless low pressure mercury lamp (EDL)
Stabilization method Reference beam method
Optical cell Fused silica (Suprasil), l: approx. 230mm, heated approx. 45°
Measuring ranges 0 – 50 µg/m³; 0 – 75 µg/m³; 0 – 500 µg/m³
Detection limit < 1 µg/m³
Response time T90 approx. 1 minute
Air supply oil-free compressed air, approx. 1.5 bar

APPROVALS & CERTIFICATIONS

  • Our products are manufactured according to the ISO 9001 quality regulations.
  • CE approved

Documentation

envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en
SM-3_Mercury_Stack_Gas_Monitor_EN_1019 SM-3_Mercury_Stack_Gas_Monitor_EN_1019
ENVEA_Process_Catalogue_EN ENVEA_Process_Catalogue_EN

Ankersmid engineers, delivers and performs service on analysis equipment, to complete CEM systems and process systems in associated analysis houses. They are used in industrial process technology, laboratories, air force, stable technology and biogas installations

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group