Dutch          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring
Home > Products > In Situ gas analysers > Protea 2000 In-Situ infrared gas analyser

Filter.

Component







































Show More


Type of measurement









Show More

Principal































Show More

Protea 2000 In-Situ infrared gas analyser

Protea 2000 In-Situ Infra-red gas analyser connected to a Protea Control Unit forms the basis of a Continuous Emission Monitoring System (CEMS). The Stack Mounted In-Situ analyser monitors the stack gas without the need for any sample handling equipment making it a cost effective solution to Continuous Emission Monitoring and Process applications. The analyser monitors the stack gases “wet”, water vapour is continuously monitored enabling the pollutant gases can be reported on a wet or dry basis.

Certification with environmental monitoring equipment standards is dependent on analyser series and application.

Certification of models includes EN 15267-3 MCERTS; EN 14181 QAL 1 and US EPA 40cfr part 60 & 75.

In-Situ Gas Analysers
In-situ Continuous Emissions Monitoring (CEM) analysers are flange mounted to the emissions point, with an in-situ sample cell inserted into the stack. Installing an in-stack CEM analyser removes the need for costly and high-maintenance sample handling components. Protea offers both Infra-Red (IR) and Ultra Violet (UV) in-situ gas analysers.

The in-situ CEM systems are multi-component and can monitor multiple gases species simultaneously. The analyser also monitors water vapour and so the pollutant gases can be reported on a wet or dry bases depending on the local environmental agencies requirements.

In-Situ Gas AnalysersThe Protea In-Situ Analyser incorporates an automatic zero and calibration gas unit and is controlled by the microprocessor in the analyser.

This allows the periodic zero and calibration to be carried out, fully challenging the system.

The stack mounted analysers can accept up to five analogue inputs from third party instruments such as Oxygen, Velocity and Particulate. This gives the system the capability to report pollutant concentrations normalised and in mass units such as kg/hr.

The stack mounted analyser is connected via a serial link to the analyser control unit, which displays, data logs and re-transmits the concentrations (ppm, mg/Nm3, %) of the monitored flue gas components. Up to eight (8) analysers can be connected to a single Protea Analyser Control Unit.

Certification with environmental monitoring equipment standards is dependent on analyser series and application. Certification of models includes EN 15267-3 MCERTS; EN 14181 QAL 1 and US EPA 40cfr part 60 & 75.

Documentation

mcert-certificate mcert-certificate
p2000-in-situ-cem p2000-in-situ-cem
in-situ-gas-analyser-ranges in-situ-gas-analyser-ranges
in-situ-cems-control-unit in-situ-cems-control-unit

Ankersmid engineers, delivers and performs service on analysis equipment, to complete CEM systems and process systems in associated analysis houses. They are used in industrial process technology, laboratories, air force, stable technology and biogas installations

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group