Hose Pump Type SR 25. Due to Its unique design this pump is extremely durable and reliable,
after 30 years of a good gasconditioning, we have a new a innovated range of sampling !
Sampling start with the sample take off point. If you have a colt spot, your measurements are worthless or your analysers can be damaged
The heated sample lines are manufactured according to the client’s specification and completely confectioned in the factory to a fixed le
The Ankersmid gas coolers series ACC ( Compressor system) and APC (Peltier system) are offering precision, safety and long-term stability for extractive analytical systems
Fast loop liquid Samplers which collect process samples without emissions to the atmosphere or exposure to the operator
Membrane pumps with rotative or linear motor, out of PTFE, Kynar PVDF or Stainless Steel. Peristaltic pumps
Automatic condensate traps or condensate collectors out of different materials,.
Rota meters out of glass or Plexiglas with or without needle valve. Flow alarm
These liquid sensors are used in gas sample conditions/systems as security alarm in case of condensate break through.
Complete range of PVDF , PP , PTFE or Stainless Steel Connectors, fittings and manifolds
Complete integrated wall mounting system and 19”-compact conditioning units or portable conditioning systems in carrying case
The ASP gas sample probes are designed for continuous gas sampling in difficult processes with gases of high or low dust content, different temperatures and extreme humidity.
A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe
Membrane pumps with rotative or linear motor, out of PTFE, Kynar PVDF or Stainless Steel
ANKERSMID Universal Condensate Separator
RVS condensaat afscheider om condensaat(vloeistof) te scheiden van verzadigd monstername gas
Universal filter with several filter elements, materials and enhancements such as moisture and alarm output
AWB Gaswas bottle. Available in different bottles. Optional: balls and drain connection options and alarm
Ankersmid aerosols / particulate filter liquid. Extremely fine filter for removing acid droplets / acid mist
A very small and extremely effective and durable filter.
Available in 0.1 microns and 2 μm
Available ot of PVDF or stainless steel.
This filter stores fully closed after fluid decisive.
Ankersmid Condensate Vessel
ACV
The ATC temperature controllers are modern microprocessor-based (PID) control devices, featuring easy handling and a digital display. The clear design of the operator control level facilitates fast and reliable adjustment.
These sample tubes are used in combination with the Ankersmid ASP probes in order to sample the gas in the optimal section of the gas-stream. For a typical installation of the probe-tip, a position in the middle third of the gas stream is advised.
PTFE, PVDF, PP, Viton tubing, connectors, nipples, 2-way ball valves - 5-way ballvalves
‘ACF’ series
The stationary gas sample probe type ASP 100 is especially designed for low-budget projects with standard process and ambient conditions. The sample probe ensures safe and reliable operation as well as easy maintenance at a wide range of applications. The innovative construction and design guarantees a perfect operation for gas measurements.
The extension tube is placed between the probe insertiontube and the insertion tube and / or the pre-filter.
after 30 years of a good gasconditioning, we have a new a innovated range of sampling !
Various gas / liquid filters
filters can be combined as well
The portable system is suitable for variable, discontinuous and continuous operation.
The ACM Control module for 19”-rack mounting is a modular system used as compact all-in-one device to monitor and control all gas sampling and gas conditioning equipment such as sample probe, cooler, sample line, pump and flow of gas media.
adsorption filter, catalysis various materials, available with various options such as liquid alarm
Gas coolers, which make use of the cooling capacity of the ambient temperature.
Stainless Steel fittings
(inches)
‘PFI’ series
Stainless Steel pipe fittings
‘PPF’ series
This unique microprocessor controlled Peltier Cooler APC 1403 has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C
Complete gas conditioning system for wall mounting.
The ASP gas sample probes are designed for continuous gas sampling in difficult processes with gases of high or low dust content, different temperatures and extreme humidity.
Ankersmid Compressor Coolers are used to lower the dew point ofhumid gas to avoid condensate entering into the gas analyser
The Ankersmid APA Series is a precise oxygen gauge for continuous monitoring purposes. The instrument is microprocessor controlled with self-diagnosis capability
It can be used for measurement of the concentration of CO, CO2 and O2 in sample gases simultaneously.
Gasboard 3000 flue gas analyzer can be used for measurement of the concentration of up to 5 gases such as SO2, NO,CO, CO2 and O2 components in sample gases simultaneously
A complete wall-mounted biogas analysis system consists of a rack type biogas analyzer Gasboard-3200, metal case, and gas conditioning system
Ankersmid Compressor Coolers are used to lower the dew point of humid gas to avoid condensate entering into the gas analyser
The compressor cooler series ACC 1xx offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied).